Boiler and Cooling Tower Water Treatment System

Modus offers boiler and cooling water treatment systems as skid mounted systems engineered to be built, shipped, and installed quickly and efficiently with minimal training required to operate. All systems are configured to use automated treatment with customizable parameters according to your system’s requirements.  Additionally, Modus treatment systems can be mounted in almost any location, offering reliable and consistent monitoring and treatment of boiler and cooling water applications.

Key Features

Modus systems can be engineered to meet your application's requirements

Water treatment systems include an automated controller for monitoring and treating according your parameters

Modus keeps robust inventory levels to ensure production is efficient and shipments are made on time

Modus provides Quality parts from the names you trust including: Walchem, LMI, Advantage, Pyxis, and more

A System Engineered For You

Configured For Your Needs

Modus Cooling Water Treatment Systems are configured to be available in various layouts using one or more feed pumps and as many sensors as you need. Skids can be assembled on a wall mount with or without a shelf or an enclosed mount. Controllers, pumps, flow meters, sensors and other related equipment are included, installed, and assembled prior to shipment.

Boiler and Cooling Sensor Parameters

Modus boiler and cooling water treatment systems can be optimized to operate in any environment while analyzing and treating the water in your application. View the table below to view the various sensors offered and relevant data to find the ideal fit for your application. 

*Additional sensors and parameters available upon request

% Range
Water GPM
0.01 - 10.0 Cell Contacting Conductivity
0-300 µS/cm
±1% of Reading
pH
-2 to 16 pH units
±0.01% of Reading
ORP / Ion Selective Electrode
-1500 to 1500 mV
±1 mV
Disinfection Sensors
-2000 to 1500 mV
±1 mV
Disinfection Sensors
0-2 ppm to 0-20,000 ppm
Varies with range and slope
Electrodeless Conductivity
500 - 2,000,000 µS/cm
±1% of Reading
Temperature
-5 to 500°F (-20 to 260°C)
±1% of reading within range
PTSA
0-300ppb (4 to 49°C)
±0.1ppb
Dissolved Oxygen
0.004-20mg/L
±0.1mg/L
Fluorescein
0-60ppb
±0.2ppb

Request a Quote